Colorless transparent liquid, similar to the smell of gasoline gas
Boiling point(101.3kPa)
49.25℃
Relative density(20℃)
0.745
Flash point
-42℃
Autoignition temperature
361℃
Explosion limit(vol)
1.4-8.7%
Fire hazard classification
AB
APPLICATION
Cyclopentane as a new type of foam foam polyurethane foam, used to replace the destruction of the atmospheric ozone layer of chlorofluorocarbons (CFCS), is now widely used in the production of fluorine-free refrigerator, freezer industry and cold storage, pipeline insulation and other fields The CFCs and HCFCs will soon be banned as the ODS deadline is approached by the Montreal Convention. Cyclopentane will become the protagonist of the polyurethane foaming field.
QUALITY STANDARD
Densityg/cm3
0.73-0.75
Cyclopentane wt%
≥98
N-pentane wt%
≤3.5
Isopentane wt%
--
Isohexane wt%
≤1.5
N-hexane ppm
≤10
Benzene ppm
≤1
Water ppm
≤100
PACKING and STORAGE
Galvanized iron drums: 148kg/drum ISO Tank:16 tons per tank.
Stored in cool, dry and well-ventilated place. Avoid exposure to sunlight and rain.